<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-05 23-06-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 54 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.4 kHz 22 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 75 kHz 9999 30,8531
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,5 dBr 8,10 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 23:06, 5.01.2025
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (54 dBuV) Max at: 75 kHz MIN: 16 kHz % above 75 kHz: 30,8531 Acquired: 2025/01/05 23:05:34 Total samples: 9999 Equivalent time: 0:08:19 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,6 dBr MIN: 7,5 dBr AVE: 8,10 dBr % above 10,0 dBr: 0,0 Last value: 8,6 dBr (2025/01/05 23:05:34) Station: 96.90 MHz, signal: 4/5 (53 dBuV) 22:59 23:00 23:01 23:02 23:03 23:04 23:05 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality